Maintenance-Object Repair Procedures
555-233-143
8-1084
Issue 1 May 2002
Table 8-444.
DSP Capacity Query Test (#1382)
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1-11
FAIL
Some DSPs on the circuit pack have failed. The FAIL code is the number of
bad DSPs reported (TN802B only).
FAIL
For the TN2302 only, the DSP failed. If it continues to fail, it will be taken out
of service.
PASS
All 11 DSPs are functioning and in-service.
0
NO
BOARD
No board was detected by the test.
1. Check the Error Log for wrong board (Error Type 125) or no board (Error
Type 131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity. If hyperactive, use the reset board UUCSS command.
3. Run the test again. If it fails, the circuit pack may be bad. Replace the
circuit pack and retest.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...