MET-LINE (MET Line)
Issue 1 May 2002
8-1105
555-233-143
MET Line Station Audits Test (#61)
This is a series of three tests that are classified as audits. These audits will abort
if attempted on an out-of-service station. Although this test never actually returns
a fail result (except for the internal system error), it is possible that it will enter
error types 257 (over current) or 513 (open circuit) into the error log. To
determine whether there are any problems that do not show up in the test result,
look for these error types in the error log. If these errors appear in the error log or
if user complaints still exist, investigate by using other circuit pack tests and by
examining the station, the wiring, and the connections. The tests are as follows:
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, check to
ensure that there is a valid board inserted.
Switchhook Audit
This is an update of the Avaya MultiVantage™ software records
according to the circuit packs’ records.
Bad Scan Inquiry
A message is sent uplink that contains a count that is generated
due to certain events relating to the link conditions. This is an
indication of data transmission problems between the MET Line
circuit pack and the voice terminal.
EPF Inquiry
The status of the Electronic Power Feed is sent uplink. Possible
conditions are: EPF-on-ok, EPF-off, EPF-no-load, and
EPF-on-overcurrent.
Table 8-453.
Test #60 MET Line Station Lamp Updates Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...