Maintenance-Object Repair Procedures
555-233-143
8-1108
Issue 1 May 2002
MET Line Ringer Update Test (#62)
In this update, a “ringer on” or a “ringer off” message is sent to the firmware to
start and stop the ringer on the set.
Table 8-455.
Test #62 MET Line Ringer Update Test
Error
Code
Test
Result
Description / Recommendation
3
ABORT
This port may have been busied out.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
present, release the port via release station extension and run the test
again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use display port UUCSSpp to determine the station extension of the port.
Use status station to determine the service state of the port. If the port is
in use, wait until the port is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Hybrid Station Ringer Update passed.
1. If complaints persist, investigate using other circuit pack tests, and by
examining the terminal, wiring, and connections.
0
NO
BOARD
The test could not relate the internal ID to the port. This could be due to
incorrect translations, no board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, check to
ensure that there is a valid board inserted.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...