Maintenance-Object Repair Procedures
555-233-143
8-1122
Issue 1 May 2002
To resolve this alarm, correct the out-of-service problem by following these
procedures:
1. See “MMI-PT” and “MMI-BD” and resolve any associated alarms.
2. If a MMI-LEV error/alarm exist and none has been raised against MMI-BD
or MMI-PT MOs, an MMI circuit pack may have been removed from service
causing the MMI-LEV error/alarm. To resolve a MMI-LEV MAJOR alarm,
restore the number of MMI ports available for service to be equal to or
more than the calculated port capacity. See the
section above for details.
3. If the error continues to alarm, escalate the problem.
System Technician-Demanded Tests:
Descriptions and Error Code
There are no System Technician-Demanded tests for MMI-LEV.