MODEM-PT (Modem Pool Port)
Issue 1 May 2002
8-1137
555-233-143
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Modem Pool Conference test (#97), you may also clear errors generated from
other tests in the testing sequence.
NOTE:
The tests in this section do not apply to Combined Modem Pool conversion
resources. The standard Digital Line and/or Analog Line port tests are run
on the ports associated with the Combined Modem Pool. Consult the test
descriptions for those MOs when repairing Combined Modem Pool
arrangements.
Table 8-466.
Modem Pool Port Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
18
0
busyout UUCSS
WARNING
OFF
release port UUCSS
130
2
2.
This error type indicates that the circuit pack has been removed or has been insane for more than 21 minutes.
To clear the error, reinsert or replace the circuit pack.
None
WARNING
ON
test port UUCSSpp sh
257
Conversion Resource Loop
(#98)
MINOR
ON
test port UUCSS s r 3
513
Modem Conference (#97)
MINOR
ON
test port UUCSS l r 3
769
Modem NPE Crosstalk (#96)
MINOR
ON
test port UUCSS l r 3
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive, ND = Nondestructive
Modem Pool NPE Crosstalk test (#96)
X
D
Modem Pool Conference test (#97)
X
D
Modem Pool Conversion Resource
Loop-around test (#98)
X
X
ND
Modem Pool Audits test (#99)
X
X
ND
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...