MODEM-PT (Modem Pool Port)
Issue 1 May 2002
8-1139
555-233-143
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
6000
ABORT
System resources needed to complete the test could not be allocated for the
digital section of the Modem Pool conversion resource. Ordinarily, this means
the conversion resource or other hardware used during the test was in use.
1. Wait 1 minute and attempt the test again.
2. If the same error occurs, use the status port command to determine
whether the Modem Pool conversion resource is in use.
3. If the conversion resource is in use, and it is absolutely necessary to test it,
the call must be dropped by issuing a busyout port UUCSS command
against the conversion resource. Run the test again.
4. If the same error occurs while the conversion resource is idle, busyout both
Modem Pool conversion resources on the TN758 Pooled Modem circuit
pack containing the conversion resource under test.
5. If the test continues to fail or abort, replace the Pooled Modem circuit pack
and retest.
6001
ABORT
System resources needed to complete the test could not be allocated for the
analog section of the Modem Pool conversion resource. Follow the test
procedures for the previous error code.
None
FAIL
The test failed. This error is internal to the Pooled Modem circuit pack and
does not involve external equipment or interfaces.
1. Busyout both of the TN758 Pooled Modem conversion resources on the
circuit pack containing the failing conversion resource.
2. If the test continues to fail, replace the Pooled Modem circuit pack and
retest.
ANY
FAIL
The NPE of the tested port was found to be transmitting in error. This condition
will cause noisy and unreliable connections.
1. If the remaining ports are currently idle (amber LED is off), reset the circuit
pack and repeat the test.
2. If the test fails again, replace the circuit pack.
PASS
The port is correctly using its allocated time slots. Investigate user-reported
troubles on this port using other port tests and by examining station, trunk, or
external wiring.
Table 8-467.
Test #96 Modem Pool NPE Crosstalk Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...