Maintenance-Object Repair Procedures
555-233-143
8-1156
Issue 1 May 2002
Analog Port Sanity Test (#963)
This test verifies that the port circuitry involved in the analog trunk testing on the
Maintenance/Test analog port is functioning properly.
This test will abort if an ATMS test call is in progress on the Maintenance/Test
analog port when the test is requested.
Table 8-476.
Test #963 Analog Port Sanity Test
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
2500
ABORT
An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals up to 3 times.
50
FAIL
The switch was unable to communicate with the port circuitry used for analog
trunk testing.
1. Reset the circuit pack via the busyout board UUCSS, reset board
UUCSS, release board UUCSS command sequence.
2. Test the port again via the test port UUCSS01 l command.
3. If the test fails again, replace the circuit pack.
PASS
The Maintenance/Test analog port analog trunk testing capability is operating
correctly.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...