M/T-BD (Maintenance/Test Circuit Pack)
Issue 1 May 2002
8-1157
555-233-143
M/T-BD (Maintenance/Test Circuit
Pack)
The Maintenance/Test circuit pack supports packet-bus fault detection and bus
reconfiguration for the port network where it is installed. The circuit pack also
provides Analog Trunk testing, and data loop-back testing of DCP Mode 2
endpoints and Digital (ISDN) Trunk facilities via the TDM bus.
Port 1 of the Maintenance/Test board is the Analog Test port which provides the
Analog Trunk testing function for Automatic Transmission Measurement System
(ATMS). ATMS is a feature in which calls are made from a device called an
Originating Test Line (OTL) over a specific trunk to a device called a Terminating
Test Line (TTL). The OTL and TTL can then send tones over the trunk under test
and determine the quality of the connection. Ports 2 and 3 are the digital ports
which provide the digital (ISDN) trunk-testing functions. Port 4 is the packet port
which provides the packet-bus maintenance function.
See
‘‘XXX-BD (Common Port Circuit Pack)’’ on page 8-1872
for circuit pack-level
errors. See also, related maintenance/test information for analog, digital, and
packet-bus ports:
■
M/T-ANA (Maintenance/Test analog port)
■
M/T-DIG (Maintenance/Test digital port)
■
M/T-PKT (Maintenance/Test packet-bus port)
Every port except the analog port (Port 1) of the Maintenance/Test board is
automatically administered when the circuit pack is inserted into the system and
automatically removed when the circuit pack is unplugged from the system. The
Analog port however, is administered via the station screen with the type “105TL”
for an OTL or a TTL. This port remains administered even after the circuit pack is
physically removed from the system. Care should be taken to remove the OTL or
the TTL before unplugging the circuit pack.
MO’s Name As
It Appears in
Alarm Log
Alarm
Level
Initial System Technician
SAT Command to Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
Full Name of MO
M/T-BD
MINOR
test board UUCSS l
Maintenance/Test circuit pack
M/T-BD
WARNING
release board UUCSS
Maintenance/Test circuit pack
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...