Maintenance-Object Repair Procedures
555-233-143
8-1166
Issue 1 May 2002
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Any
FAIL
The NPE of the tested port was found to be transmitting in error. This will
cause noisy and unreliable connections.
1. If the remaining ports are currently idle (amber LED is off), try to reset the
circuit pack. Then repeat the test.
2. If the test fails again, replace circuit pack.
PASS
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests and by examining station,
trunk, or external wiring.
Table 8-477.
Test #9 NPE Cross Talk Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page