Maintenance-Object Repair Procedures
555-233-143
8-1174
Issue 1 May 2002
Hook State Inquiry (#566)
This test ensures that the Maintenance/Test digital port maintenance software and
call processing agree on the on-/off-hook status of the Maintenance/Test digital
port.
Table 8-481.
Test #566 Hook State Inquiry
Error
Code
Test
Result
Description / Recommendation
1
ABORT
Switch hook audit timed out. No response was received from the circuit pack
for information about the switch hook state.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, replace the circuit pack and repeat the test.
3. If the test continues to abort, escalate the problem.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Any
FAIL
Internal system error. This test should never return a failure.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail reset the circuit pack via the busyout board
UUCSS, reset board UUCSS, and release board UUCSS command
sequence.
3. Retry the command at 1-minute intervals up to 5 times.
4. If the test continues to fail, escalate the problem.
PASS
Call processing and Maintenance/Test digital port maintenance software agree
on the Maintenance/Test digital port hook state.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...