Maintenance-Object Repair Procedures
555-233-143
8-1194
Issue 1 May 2002
DS1 OPS Switchhook Inquiry Test (#312)
This test initiates the Switchhook Audit test. The test queries the switchhook state
of the Off-Premises-Station in switch software. If the state in switch software
disagrees with the state on the DS1 Interface circuit pack, then the state in the
switch software is updated to match the state on the DS1 Interface circuit pack.
Table 8-488.
Test #312 DS1 OPS Switchhook Inquiry Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1004
ABORT
The port has been seized by a user for a valid call. Use the status station
command to determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
Test failed due to incompatible configuration administered in station
administration.
1. Using the display station command, verify that the station is not the 24th
port of the DS1 Interface circuit pack while common channel signaling is
specified. Use the display ds1 command to check the signaling type of
the DS1 circuit pack.
1006
ABORT
The test was aborted because the station is out of service. This condition may
be accompanied by an error type 18 entry in the error log. You may want to
determine why the station was taken out of service. (When stations are taken
out of service by maintenance software, the problems that led up to that must
be cleared.)
1. Use the status station command to check the state of the port. If the port
is indeed out of service, enter the release station command to bring the
station back into service.
2. Retry the command at 1-minute intervals up to 5 times.
1020
ABORT
The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD/UDS1-BD errors in Hardware Error Log. If present, see
the appropriate error
‘‘DS1-BD (DS1 Interface Circuit Pack)’’ on page
.
2. Retry the command.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...