PDMODULE (Processor Data Module) TDMODULE
(Trunk Data Module)
Issue 1 May 2002
8-1205
555-233-143
With the port still in loop-around mode, the S Channel Loop-around test is
performed next. This test consists of sending four different transparent patterns to
the on-board microprocessor, receiving them back, and comparing them.
The third test is a loop around test for the secondary information channel. It is
performed only if a secondary data module is assigned to the port.
The fourth test is a Conference test of the primary channel. This is the same test
as Analog Line Conference test (#6).
Only one result is reported for the three tests run. If any test fails or aborts, the
sequence is stopped.
Table 8-493.
Test #13 Information and Control Channel Local Loop Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the data module
extension. Then use status data module command with the extension
number to determine the service state of the data module. If the service
state indicates that the data module is in use, then the port is unavailable
for certain tests. You must wait until the port is idle before retesting.
2. If the port status is idle, then retry the command at 1-minute intervals up to
5 times.
1001
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some tone detectors may
be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...