Maintenance-Object Repair Procedures
555-233-143
8-1206
Issue 1 May 2002
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the data module
extension. Then use status data module command with the extension
number to determine the service state of the data module. If the data
module is in use, wait until the port is idle before retesting.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
7
FAIL
Conference test failed on the primary information channel. In some cases,
user may not notice disruption in service. In extreme cases, conferencing
feature may not work at all.
14
FAIL
The primary information channel is not transmitting properly. User impact may
range from noticing nothing to not being able to use this port.
15
FAIL
The control channel between the processor and Digital Line circuit pack is not
transmitting properly. This can cause a wide range of effects. The user may
notice nothing or the port may be totally unusable. This could also disrupt other
users.
1. Run circuit pack tests to check the Tone Generator and the Tone Detector
circuit packs using the test board UUCSS short command.
2. Resolve any problems that are detected on the Tone Generator circuit pack
or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning
properly, and the test still fails, replace the Digital Line circuit pack.
16
FAIL
The secondary information is not transmitting properly. This can cause a wide
range of effects. The user may notice nothing or the port may be totally
unusable.
1. To be sure that this is not an intermittent problem, repeat this test up to up
to 10 times to make sure it continues to pass.
2. If complaints still exist (poor data transmission), examine the data module,
connections, and wiring.
PASS
Information and Control Channel Local Loop test passed. Every channel is
transmitting properly.
Table 8-493.
Test #13 Information and Control Channel Local Loop Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...