Maintenance-Object Repair Procedures
555-233-143
8-1210
Issue 1 May 2002
Table 8-495.
Test #175 Data Module Internal Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
1000
ABORT
System resources required to run this test are not available. The port may be
in use on a valid call. Use status data-module to determine when the port is
available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
Loop around testing is not enabled on the data module administration form.
1. Set
Loop-Around Test
field to y on the data module administration
form.
1042
ABORT
The port under test is a TTI port and thus has only default translations and no
assigned extension. The test requires an extension assigned to the port being
tested.
1. If there is a need to execute the test on this particular port, then you must
fully administer the port so that is has an assigned extension.
1180
ABORT
A Maintenance/Test circuit pack digital port is not available to carry out the test.
1. Check to see if the Maintenance/Test digital ports are present (use the list
config board command and look for ports 02 and 03).
2. If the digital ports (02 and 03) on the M/T-BD are absent, see
(Maintenance/Test Digital Port)’’
3. If the digital ports are present, try the command again at 1-minute intervals
up to 5 times.
1181
ABORT
No time-slots available to connect digital ports for the test.
1. Try the command again at 1-minute intervals up to 5 times.
1182
ABORT
Internal system error. Failed to connect the digital ports with time-slots.
1. Retry the command at 1-minute intervals up to 5 times.
1340
ABORT
No Maintenance/Test digital port is currently available to perform this test.
1. Use list config to determine whether any Maintenance/Test digital ports
(ports 02 and 03 on the Maintenance/Test circuit pack) are present in the
system. Because at least one Maintenance/Test circuit pack must always
be present in the PN of S8700 Multi-Connect configurations, there should
be at least two such ports present. If the ports are present, proceed to step
2. Otherwise, determine why no ports appear in the list config display.
See
‘‘M/T-DIG (Maintenance/Test Digital Port)’’
(Maintenance/Test Circuit Pack)’’
2. Look for M/T-DIG errors in the Error Log. If present, see
(Maintenance/Test Digital Port)’’
3. If the ports are present and no errors are logged against them, retry the
command at 1-minute intervals up to 5 times.
4. If the test continues to abort, replace the Maintenance/Test circuit pack.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...