PE-BCHL (PRI Endpoint Port)
Issue 1 May 2002
8-1219
555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. These error types indicate a disagreement between this switch and the
terminal adapter at the other end of the connection with regard to the ISDN
call state of the PRI endpoint port. This switch will automatically try to
recover by clearing the call (the call will be torn down). Use the status
pri-endpoint extension command to determine the state of the port.
When running the short test sequence, pay close attention to the results of
the Call State Audit test (#257).
b. This is a software audit error that does not indicate any hardware
malfunction. Run the short test sequence, and investigate associated
errors.
c. The PRI endpoint port has been busied out by busyout pri-endpoint
extension or busyout port UUCSSpp. No wideband calls can be made to
this port, although wideband calls can still be made to other ports within
this PRI endpoint if they are in service.
Table 8-497.
PRI endpoint port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
Any
None
test port UUCSSpp sh r 1
15 (b)
Any
Audit and Update test (#36)
18 (c)
0
busyout pri-endpoint
extension
busyout port UUCSSpp
release pri-endpoint
extension release port
UUCSSpp
129 (d)
None
WARNING
OFF
test port UUCSSpp sh r 1
130 (e)
None
WARNING
ON
test port UUCSSpp sh
257 (f)
Any
None
test port UUCSSpp sh r 1
513 (g)
Any
None
WARNING
OFF
test port UUCSSpp sh r 1
769 (f)
Any
None
test port UUCSSpp sh r 1
1281 (h)
Any
Conference Circuit test (#7)
MINOR
ON
test port UUCSSpp l r 4
1537 (i)
Any
NPE Crosstalk test (#6)
MINOR
ON
test port UUCSSpp l r 3
1793 (j)
Any
None
test port UUCSSpp sh r 1
3073 (k)
Any
Service State audit (#256)
test port UUCSSpp sh r 2
3585 (l)
Any
None
None
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...