Maintenance-Object Repair Procedures
555-233-143
8-1226
Issue 1 May 2002
Signaling Link State Check Test (#255)
As noted in the preceding general description, operation of the PRI endpoint port
depends on the health of the UDS1 interface circuit pack and System Link for
proper operation. This test checks the status of those critical elements.
Table 8-501.
Test #255 Signaling Link State Check Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated with this PRI
endpoint extension is detached from the circuit pack. This is a normal abort
when the rollabout video feature is enabled.
1. Either reconnect the disconnected PRI terminal adapter or disable the
rollabout video feature on this circuit pack. To do the latter, enter change
ds1 UUCSS and set the
Alarm when PRI Endpoint Detached?
field to y.
4
FAIL
There is a problem with the Signaling Channel and/or with the System Link.
1. Consult procedures for the ISDN-GRP and SYS-LINK. See also
ISDN-LNK for useful information.
8
FAIL
There is a problem with the UDS1 interface circuit pack.
1. Consult procedures for UDS1-BD.
PASS
The signaling link hardware is OK.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...