Maintenance-Object Repair Procedures
555-233-143
8-1296
Issue 1 May 2002
Notes:
a. An error took place in generating the error code.
b. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_EAL. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (10003
points to port network 4) List config port-network gives the cabinet
number associated with a port network.
c. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_INL. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (10003
points to port network 4) List config port-network gives the cabinet
number associated with a port network.
d. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_HW. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (10203
points to port network 4.) List config port-network gives the cabinet
number associated with a port network.
e. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_PER. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (10303
points to port network 4.) List config port-network gives the cabinet
number associated with a port network.
f. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_DS1. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (10403
points to port network 4.) List config port-network gives the cabinet
number associated with a port network.
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
18
None
busy PNC-DUP
WARNING
ON
release pnc-dup
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...