Maintenance-Object Repair Procedures
555-233-143
8-1320
Issue 1 May 2002
Table 8-530.
Test #1275 SCOTCH Synchronous Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
1000
ABORT
The port is in use or PPP link is connected.
1. Determine when the port is available for testing (status clan-port
UUCSSpp).
2. The port may be forced to the idle state by executing a busyout port
UUCSSpp command.
NOTE:
This command is destructive, causing every call and link using the port
to be torn down.
1002
ABORT
No TDM bus timeslots available for the test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
1963
ABORT
Firmware indicates that the port is in use or ppp link is connected.
1. Determine when the port is available for testing (status clan-port
UUCSSpp).
2. The port may be forced to the idle state by executing a busyout port
UUCSSpp command.
NOTE:
This command is destructive, causing every call and link using the port
to be torn down.
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
1. If this problem persists, reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and release board UUCSS).
2. If the problem persists, replace the circuit pack.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2. Escalate if the problem persists.
2100
ABORT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
FAIL
C-LAN circuit pack detected test failure.
1. If the problem persists, reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and release board UUCSS).
2. If the problem persists, replace the circuit pack.
PASS
Port circuitry functioning properly.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...