Maintenance-Object Repair Procedures
555-233-143
8-1322
Issue 1 May 2002
Session Status Test (#1286)
This nondestructive test determines the status of every PPP port session. This
test queries the system software on port session status.
2100
ABORT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2. Escalate if the problem persists.
1003
FAIL
Ping to the destination failed due to on-board problem.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the problem persists, reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and release board UUCSS).
3. If the problem persists, re-administer the PPP connection through a
different PPP port, if available.
4. If the problem still persists, or if there are no other available PPP ports,
replace the circuit pack.
1007
FAIL
Ping to the destination failed due to the destination down.
1. A PPP destination or a component in the path (e.g., DS1 trunk) may be
down. Check the status of the destination or other components in the path.
2. If the destination and every component in the path is in-service, ping the
PPP destinations (ping ip-address xxx.xxx.xxx.xxx).
3. Escalate if the problem persists.
PASS
TCP/IP Ping test (#1281) is successful.
If the system software indicates that:
Then the switch:
Every port session is up (ALL UP)
Raises no alarm, or retires alarm
Some port sessions are up (SOME UP)
Raises MINOR alarm
Every port sessions is down (ALL DOWN)
Raises MINOR alarm
Table 8-531.
Test #1281 TCP/IP Ping Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...