Maintenance-Object Repair Procedures
555-233-143
8-1338
Issue 1 May 2002
Station Status and Translation Audits and
Updates Test (#36)
This test updates the analog port’s message lamp state (if it has one) and
translations with information in the software.
Table 8-541.
Test #36 Station Status and Translation Audits and Updates
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1004
ABORT
The port was seized by a valid call during the test, and the test was aborted.
Use the display port UUCSSpp command to determine the station extension.
Use the status station command to determine the service state of the port. If
the port is in use, wait until port is idle.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1
FAIL
This does not indicate a hardware problem. The switchhook audit failed. The
other updates were not performed because of this failure. This may occur
when the audit is performed at the same time the terminal equipment goes
off-hook. Use the status station command to determine when the port is
available.
1. Retry the command at 1-minute intervals up to 5 times.
5
FAIL
This may be an internal software error. The message waiting lamp update
failed. The translation and ringer updates were not performed because of this
failure.
1. Retry the command at 1-minute intervals up to 5 times.
7
FAIL
The translation update failed. There may be an internal software error. The
ringer update was not performed because of this failure.
1. Retry the command at 1-minute intervals up to 5 times.
8
FAIL
This does not indicate a hardware problem. There may be an internal software
error. The ringer update failed.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The software and the port processor have the same status. User-reported
troubles on this port should be investigated by using other port tests, by
examining station wiring, or by examining the station.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...