RDIG-STA (Remote Digital Station)
Issue 1 May 2002
8-1345
555-233-143
A confirmation is returned if the download request is accepted. A busy
tone is returned if the request is made from a different station when the
target station is off-hook.
As a result of an entry of a Refresh Terminal Parameters Facility Access
Code, the first three green call appearance LEDs on the 84xx 603x
terminal are turned on for three seconds, if the station was successfully
downloaded. This is not true for the 302B1 terminal.
There is no visible display on a station for the other background or demand
download actions. As described below, the status station and status
attendant screens can be used to check the download status of a specified
terminal.
Status of Parameter Downloads
The status station and status attendant screens display the current download
status of individual 84xx, 603, and 301B1 terminals in the
Download Status
field. The possible download states are:
Possible reasons for no terminal download include:
■
Terminal is off-hook.
■
Terminal detected a bad checksum.
■
Terminal detected a bad or missing EEPROM (refer to hardware error log).
■
Terminal is busy programming data from a previous PROGRAM message.
■
Terminal is in the Programming Disabled state.
■
Terminal is in the Local Program Options mode.
■
Terminal is disconnected or out of service (use status station command).
Status
Terminal Download State
Complete
The terminal successfully downloaded sometime in the past.
Pending
The system is waiting to download the terminal. This may require the execution
of a background periodic test, which could take more than an hour. A demand
download as described above may also be used to initiate an immediate
download.
Not Applicable
Not a programmable terminal.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...