REM-OFF (Remote Office)
Issue 1 May 2002
8-1355
555-233-143
REM-OFF (Remote Office)
An instance of this MO (REM-OFF) is associated with every Remote Office box
that is administered on the switch. This MO monitors keep alive and periodic
PING test failures, and if these errors occur, they are logged against this MO.
Error Log Entries and Test to Clear Values
C-LAN Board
Location
The physical location of the circuit pack in CCcss format
(cabinet, carrier, slot)
Number of
Routes Removed
The number of routes that were deleted from the TN799DP
(C-LAN) route tables
Number of
Routes Added
The number of routes that were added from the TN799DP
(C-LAN) route tables
MO’s Name (in
Alarm Log)
Alarm
Level
Initial SAT Command to Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
Full Name of MO
REM-OFF
MINOR
ping node-name | ip-address addr
Remote Office
REM-OFF
WARNING
ping node-name | ip-address addr
Remote Office
Table 8-549.
Analog Line Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Of
f
Board
Test to Clear Value
1(a)
A ping test to an
endpoint has failed
MINOR
OFF
ping node-name | ip-address addr
257(b)
See
note
(b)
A keep alive
update request has
exceeded the time
limit for an endpoint
Log only
OFF
ping node-name | ip-address addr
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...