Maintenance-Object Repair Procedures
555-233-143
8-1378
Issue 1 May 2002
d. The physical neighbor type does not match administration. If the aux data
is 1, the type of neighbor administered is an SNI and the type of neighbor
connected is an EI. If the aux data is 2, the type of neighbor administered
is an EI and the type of neighbor connected is an SNI.
To resolve error type 6002 with aux data 1, refer to FAIL code 136 for test
759. To resolve error type 6002 with aux data 2, refer to FAIL code 137 for
test 759.
e. The neighbor location does not match administration.
To resolve this error, refer to FAIL code 138 for test 759.
f. A peer link does not exist to another equipped SNI. The aux data equals
the slot number of the SNI to which this SNI or SNC does not have a peer
link. To resolve this error, refer to the FAIL code for test 759 corresponding
to the aux data on the following table:
g. A link does not exist to one of the SNCs. If the aux data is not 1 or 2, the
link from this SNI to the active SNC does not exist. If the aux data is 1, the
link from this SNC to the active SNC does not exist. If the aux data is 2, the
link from this SNC to the standby SNC does not exist.
To resolve this error, refer to FAIL code 112 for test 759.
Aux Data (slot no.)
Test 759 FAIL Code
2
102
3
103
4
104
5
105
6
106
7
107
8
108
9
109
13
113
14
114
15
115
16
116
17
117
18
118
19
119
20
120
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...