SN-CONF (Switch Node Configuration)
Issue 1 May 2002
8-1383
555-233-143
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
If this test fails, one or more administered circuit packs in this switch node
carrier did not respond with a “board insertion” uplink message. Verify that
administered SNI and SNC boards match the physically installed SNI and SNC
boards by entering list config carrier UUC. The command output will show
"NO BOARD" for every board that is administered, but not inserted.
■
If every administered board is inserted, run this test again.
■
If administration does not match the physical configuration, and is
correct, insert the missing circuit packs in this switch node carrier.
■
If administration does not match the physical configuration, and is
incorrect, change the administration, and run this test again.
■
If none of the administered boards in this switch node carrier were
inserted, fix any other SN-CONF errors by following the associated
repair procedures for SN- CONF. Use display errors with
category pnc to view SN-CONF errors. Next check if any INLs,
LNLs, or RNLs are down with list sys-link. If any INLs, LNLs, or
RNLs are down, see
problems.
PASS
If this test passes, every administered circuit pack in this switch node carrier
was inserted.
Table 8-565.
TEST #760 Processor Route Audit Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...