SNC-BD (Switch Node Clock Circuit Pack)
Issue 1 May 2002
8-1419
555-233-143
Switch Node Clock Reset Test (#780)
This test is destructive.
This test resets the SNC circuit pack via the reset board UUCSS command when
an SNC circuit pack location is entered. If the system has PNC duplication, the
active SNC on the active PNC cannot be reset.
If the SNC is active and the reset board command is executed, an SNI in the
same carrier as the SNC will be told by software to reset the SNC via the TPN
link. If no inserted SNIs in the same carrier as the SNC can successfully reset the
SNC, software will send a “reset” message directly to the SNC. Software first tries
to reset the SNC via an SNI in case the SNC is insane because the latter method
(sending the “reset” message directly to the SNC) will not work if the SNC is
insane.
If an active SNC is reset and a standby SNC exists in the same switch node
carrier, the standby SNC will become active. The reset board command should
not be used to make a standby SNC active. Instead, the set switch-node-clock
UUCSS command should be used.
If the SNC is standby and the reset board command is executed, the active SNC
is told by software to reset the standby SNC via the TPN link.
An SNC should be reset instead of reseating the circuit pack. The reset board
command should almost never be used on an SNC. It may be necessary to use
the reset board command if the SNC circuit pack gets into a mode where it
cannot communicate with software.
Table 8-572.
TEST #780 Switch Node Clock Reset Test
Error
Code
Test
Result
Description / Recommendation
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABORT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABORT
The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2302
ABORT
Software received unexpected message data from the SNC circuit pack.
1. Retry the command at 1-minute intervals up to 3 times.
2303
ABORT
The SNC circuit pack responded that the software test requested is not valid.
1. Retry the command at 1-minute intervals up to 3 times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...