SNI-BD (SNI Circuit Pack)
Issue 1 May 2002
8-1439
555-233-143
Error Log Entries and Test to Clear Values
Table 8-575.
SNI Board Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each
appropriate test’s description, and follow its recommended procedures.
0
Any
Any
Any
test board UUCSS r 1
1 (b)
any
failure audit (#777) (a)
MAJOR
MINOR
WARNING
ON
test board UUCSS r 1
18 (c)
0
busyout board UUCSS
WARNING
OFF
release board UUCSS
125( d)
None
MINOR
ON
257 (e)
any
failure audit (#777) (a)
MAJOR
MINOR
WARNING
OFF
test board UUCSS r 1
513 (f)
any
failure audit (#777) (a)
MAJOR
MINOR
WARNING
OFF
test board UUCSS r 1
769 (g)
any
failure audit (#777) (a)
MAJOR
MINOR
WARNING
OFF
test board UUCSS r 1
1025 (h)
any
failure audit (#777) (a)
MAJOR
MINOR
WARNING
ON/
OFF
test board UUCSS r 1
1281 (i)
any
failure audit (#777) (a)
MAJOR
MINOR
WARNING
ON
test board UUCSS r 1
1537 (j)
any
failure audit (#777) (a)
MAJOR
MINOR
WARNING
OFF
test board UUCSS r 1
2561 (k)
any
failure audit (#777) (a)
MAJOR
MINOR
WARNING
ON
test board UUCSS r 1
2817 l)
any
failure audit (#777) (a)
MAJOR
MINOR
WARNING
ON
test board UUCSS r 1
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...