SNI-BD (SNI Circuit Pack)
Issue 1 May 2002
8-1471
555-233-143
2316
ABORT
The reset of the SNI circuit pack was attempted via the connected DS1C circuit
pack. This ABORT code indicates that the fiber is not administered, but in this
particular case it also indicates a software problem.
1. Retry the command at 1-minute intervals up to 1 time.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
PASS
The “reset” message was sent out successfully to the active SNC or to the
SNI’s neighbor. A PASS does not necessarily mean the SNI circuit pack was
successfully reset. The reset can be verified by checking that the red and
green LEDs turn on and then turn off. If an SNI circuit pack fails one of the
firmware tests run during its reset sequence, the red LED will stay on and the
circuit pack should be replaced.
0
NO
BOARD
No board was detected by the test.
1. Check that board is properly translated and inserted.
2. Run the test again. If it fails, reset the board. An SNI should be reset
instead of reseating the circuit pack. The reset board command should
almost never be used on an SNI. It may be necessary to use the reset
board command if the SNI circuit pack gets into a mode where it cannot
communicate with software. If an SNI with active errors and alarms is
reset, the errors and alarms may take a while to come back, therefore the
reset board command can mask real problems.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
the board and retest.
Table 8-580.
TEST #761 Switch Node Interface Reset Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...