SYS-LINK (System Links)
Issue 1 May 2002
8-1535
555-233-143
The status sys-link location command shows the state of both the hardware
paths (current and faulted) along with the state of each of the components in the
hardware path. When analyzing any system link problem:
1. Look for alarms on the components listed under desired hardware path.
2. If any alarms are present, then follow the maintenance procedures for the
alarmed components to clear those alarms first.
NOTE:
For systems using ATM-EI (TN2305/6 circuit packs) and where link
alarms are present, see
‘‘ATM-BCH (ATM B-Channel Trunk)’’
and the
section in
.
3. When every component is alarm free, wait for 3 minutes to allow the links
to recover.
4. Test the system link (test sys-link PCSSpp long clear), and notice any
tests that fail.
5. If there are any failures, fix the problems indicated by the tests and repeat
the procedure.
Error Log Entries and Test to Clear Values
Table 8-595.
Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
13 (a)
System Link Status
(#985)
MINOR
WARNING
OFF
257 (b)
WARNING
OFF
test sys-link UUCSSpp l cl
513 (c)
WARNING
OFF
test sys-link UUCSSpp l cl
772 (d)
WARNING
OFF
test sys-link UUCSSpp l cl
1025 (e)
WARNING
OFF
test sys-link UUCSSpp l cl
1281 (f)
WARNING
OFF
test sys-link UUCSSpp l cl
1537 (g)
WARNING
OFF
test sys-link UUCSSpp l cl
1793 (h)
WARNING
OFF
test sys-link UUCSSpp l cl
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...