Additional Maintenance Procedures
555-233-143
5-40
Issue 1 May 2002
The detailed report lists measurements for each trunk-group member. The
summary reports lists trunk groups as a whole. The measurements that are
displayed depends on what type of test, if any, was last run on the trunk, and the
capabilities of the TTL on the switch at the far end of the trunk. See
for a description of the test analog-testcall command. A
blank line indicates that no test data is available for that trunk or group.
The number of pages of each report is dependent upon the selection criteria and
the number of outgoing trunks in the system. About 10 measurements can be
listed on a page on the administration terminal, or about 50 measurements can be
listed on a printer. By default, reports list every measurement. Filtering can be
used to limit the output. For example, the report can be set up to print only failed
measurements.
The syntax of the command is as follows:
list testcalls detail | summary
[port UUCSSpp]
[grp group#] [to-grpgroup#]
[mem member#] [to-memmember#]
[resultresultID> | not-resultresultID]
[count#] [print | schedule]