SYS-PRNT (System Printer)
Issue 1 May 2002
8-1541
555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. The System Printer Link has been busied out.
b. A failure was encountered while attempting to set up the System Printer
Link. This attempt could have been initiated by either Report Scheduler
software or by link maintenance during automatic link retry or as a result of
a Link Retry test (#215) request. The Aux Data field indicates the
following:
See the preceding section
‘‘Procedures for Restoring the System Printer
for recommended maintenance strategy.
c. The SYS-PRNT was interrupted for one of the following reasons:
■
The cable to the SYS-PRNT output device is disconnected
■
The SYS-PRNT output device is powered off
■
The data extension to which the SYS-PRNT output device connects
has been busied out
■
Internal software error
Check the connectivity of the wires and cables among the wall jacket, data
module, and SYS-PRNT output device. Follow the instructions provided in
‘‘Procedures for Restoring the System Printer Link’’ on page 8-1540
Table 8-597.
SYS-PRNT Maintenance Error Log Entries
Error
Type
Aux Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear
Value
0
0
Any
Any
Any
test sp-link
18 (a)
0
busyout sp-link
WARNING
OFF
release sp-link
257(b)
1, 3 4, 5, 6
Link Retry test (#215)
MINOR
1
WARNING
1.
Minor alarms may be downgraded to Warning alarms based on the value used in the set options command.
OFF
test sp-link l
513 (c)
0
None
MINOR
OFF
test sp-link
1
No C-LAN port available. See
‘‘CLAN-BD (Control LAN Circuit Pack)’’ on
for explanation.
3, 4
Time-out during setup attempt. Most likely due to problem with physical
link or printer status.
5
Internal system error. Most likely temporary/sporadic failure.
2, 6
The data module the printer is trying to use is busy with another call. Use
the Status data module command to determine when the port is
available for testing.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...