SYS-PRNT (System Printer)
Issue 1 May 2002
8-1543
555-233-143
Link Retry Test (#215)
This test sends a message to the System Printer management software process
instructing it to make a data call to the extension connected to the printer. If the
System Printer link is already up, this test passes without making any data call.
Table 8-599.
TEST #215 Link Retry Test
Error
Code
Test
Result
Description / Recommendation
10, 20
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to two times.
30
ABORT
Internal system error.
1. See
‘‘Procedures for Restoring the System Printer Link’’ on page 8-1540
for recommended maintenance strategy.
1010
ABORT
The System Printer Link has been busied out.
1. Enter the release sp-link command to release the System Printer Link
from the busyout state.
2. Reissue the test sp-link long command to execute the test.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to five times.
FAIL
The System Printer Link CANNOT be established.
1. See
‘‘Procedures for Restoring the System Printer Link’’ on page 8-1540
for recommended maintenance strategy.
PASS
The System Printer Link is up.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...