TBRI-PT (ISDN Trunk-Side BRI Port)
Issue 1 May 2002
8-1567
555-233-143
Table 8-608.
Test #618 BRI Port Local LAN Loop Around
Error
Code
Test
Result
Description / Recommendation
1015
ABORT
The port is not out-of-service.
1. Use the status bri-port UUCSSpp command to determine the status of
the port.
2. If it is in use, wait until it is idle, and then use the busyout port UUCSSpp
command to place it in the out-of-service state and repeat this test.
!
CAUTION:
Since the busyout command is destructive, execution of this
command prior to the port being idle causes every call associated
with the BRI port to be torn down.
1139
ABORT
The Packet bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet bus.
2. Run the test port long UUCSSpp command and verify the repair by
viewing the results of the BRI Port Local LAN Loop-Around test (#618).
1141
ABORT
The PKT-CTRL is out-of-service.
1. Follow the repair procedures for the PKT-CTRL.
2. Run the test port long UUCSSpp command and verify the repair by
viewing the results of the BRI Port Local LAN Loop-Around test (#618).
2012
2100
ABORT
Internal system error
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The Loop-Around test has failed.
1. If the test fails repeatedly, attempt to reset the circuit pack with the
busyout board UUCSS and the reset board UUCSS commands if the
other ports on the board are idle.
2. If the test fails again, execute test pkt P. If this fails, follow failure
procedures in the PKT-BUS section.
3. If the tests in Step 2 pass, the problem is local to the BRI board. Replace
the trunk circuit pack.
PASS
The BRI Port Local LAN Loop-Around test passed.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...