TBRI-TRK (Trunk-Side ISDN BRI)
Issue 1 May 2002
8-1579
555-233-143
Service State Audit (#256)
This test is nondestructive.
This test performs a service state audit on an ISDN B channel. The test passes if
Call Processing informs Maintenance that the Restart message was transmitted
successfully, or if the B channel was busy and could not send the message.
The test fails if the board is not inserted or translated properly, or if a reply is not
received within a certain amount of time.
The test aborts if the signaling link is disconnected, if a message is already
outstanding, or if the necessary resources could not be allocated.
To investigate the service state of a TN2185 Trunk-Side ISDN-BRI channel, issue
the status trunk trunk-group/trunk-member command.
Table 8-615.
Test #1251 Signaling Link State Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1018
ABORT
The test is disabled.
1. Enable the test by entering enable test #1251.
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
8
FAIL
The signaling link is down.
1. Consult the procedures for the TBRI-PT MO.
9
FAIL
The port is out of service.
1. Return the port to an in-service state.
PASS
The signaling link is connected and operating normally.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...