Maintenance-Object Repair Procedures
555-233-143
8-1630
Issue 1 May 2002
1004
ABORT
The port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1018
ABORT
Test disabled via administration. This only applies to analog stations.
1. To enable test, set the Test field on the station administration screen for the
particular analog station being tested to “y.” Use the change station
extension command.
1020
ABORT
The test did not run due to a previously existing error on the specific port or
because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or circuit pack,
and attempt to diagnose the previously existing error.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABORT
At least one of the following errors is found on the DS1 circuit pack: 1281 –
Loss of signal,1793 – Blue alarm, 2049 – Red alarm, 2305 – Yellow alarm, or
1537 – Hyperactivity.
Look for the previous error types in the Hardware Error Log, and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
Table 8-633.
Test #7 Conference Circuit Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...