Maintenance-Object Repair Procedures
555-233-143
8-1650
Issue 1 May 2002
Tie Trunk Seizure Test (#73)
and Tie Trunk Dial Test (#747)
For wink-start, delay-dial and TN2140 (cont-seize-ack or discont-seize-ack)
trunks, this test activates the M lead and checks for a response from the far end
within 10 seconds.
For TN497, the test seizes a trunk and outpulses a pause. The port reports uplink
the result of the seizure. This test can be disabled via the
Test
field on the trunk
group administration form.
For TN439, Test #747 is run instead of #73. This test seizes a trunk and
outpulses a pause digit. This test aborts on ports administered as access
endpoints.
Table 8-642.
Test #73,#747 Tie Trunk Seizure Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The trunk may be
busy with a valid call. Use the display trunk xx to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait until
the port is idle before retesting.
1. If the port status is active, but the port is idle (no calls), then check the
Error Log for Error Type 1025 (see Error Log table for description of this
error and required actions). The port may be locked up. The far-end PBX
may not be releasing.
2. If the port status is idle, then retry the command at 1-minute intervals up to
5 times.
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
Use the display trunk xx to determine the trunk group/member number of the
port. Use the status trunk command to determine the service state of the port.
If the service state indicates that the port is in use, then the port is unavailable
for certain tests. You must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
This test is not valid for this trunk translation. Must be a wink-start or delay dial
trunk and must be outgoing or 2-way for this test to run. For the TN2140, the
trunk must also be continuous-seize-ack or discontinuous-seize-ack.
1. Check trunk translation. If it is not a wink-start or delay dial trunk, this abort
message should be ignored.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...