TONE-PT (Tone Generator)
Issue 1 May 2002
8-1683
555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. A failure in the tone generation facility on the indicated circuit pack has
been detected. Replace the circuit pack. See
Tone-Clock Circuit Pack’’ on page 8-1666
b. The indicated IPSI or Tone-Clock circuit pack has been made unavailable
via the busyout Tone-Clock UUC command. It only applies to systems
which have the high- or critical-reliability option administered, because only
a standby Tone-Clock circuit may be made busy by that command. To
resolve this error, execute the release tone-clock UUC command for the
alarmed circuit pack.
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11-minutes. To clear the error, reinsert or
replace the circuit pack.
d. The tone generation facility is having problems verifying that tones have
been connected as requested.
e. The tone generation facility may or may not be able to generate tones.
Table 8-652.
Tone Generator Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test tone-clock UUC r 1
1 (a)
17664
Tone Generator Audit/
Update test (#41)
MAJOR/
MINOR
2
2.
MAJOR alarm if the alarmed IPSI or Tone-Clock circuit pack is not duplicated; MINOR if it is duplicated within
the same EPN.
ON
test tone-clock UUC r 2
18 (b)
0
busyout tone-clock UUC
WARNING
OFF
release tone-clock UUC
130 (c)
None
MINOR
ON
test tone-clock UUC Sh
257 (d, f)
17667
None
MINOR
ON
513 (e, f)
17666
Tone Generator Audit/
Update test (#41)
MINOR
ON
test tone-clock UUC r 3
769
Any
Transmission test (#40)
MAJOR/
MINOR
ON
test tone-clock UUC r 3
1025
Crosstalk test (#90)
MAJOR/
MINOR
ON
test tone-clock UUC l r
2
1281 (g)
Any
Tone Generator Audit/
Update test (#41)
MINOR
ON
test tone-clock UUC r 3
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...