TONE-PT (Tone Generator)
Issue 1 May 2002
8-1689
555-233-143
c. Error code 115 may also be caused by TDM bus corruption. This normally
means a physical problem with bent backplane pins, TDM/LAN bus
cabling, or TDM/LAN bus terminators. Such physical problems should
especially be suspected if board replacement or other physical activity has
occurred just before this error is observed.
Use display errors to look for errors on other circuit packs in the carriers of
the same port network as the indicated Tone-Clock circuit. If any are
found, they should be resolved if possible, and the IPSI or Tone-Clock
circuit pack retested. If this does not clear the problem, the IPSI or
Tone-Clock circuit pack should be replaced and the new one tested. If the
problem persists, follow instructions for TDM bus maintenance in this
manual.
Tone Generator Update/Audit Test (#41)
The active tone generation facility is refreshed with all the time slot tone
information. This test also triggers in-line error messages the IPSI or Tone-Clock
circuit pack generates when it detects problems by itself.
A check is also made between the type of Tone-Clock being tested and the type of
Tone-Clock needed based on system administration. The administration on the
system-parameters country-options form may imply that a TN780 is required.
Table 8-654.
Test #41 Tone Generator Update/Audit Test
Error
Code
Test
Result
Description / Recommendation
none
ABORT
The system was not able to allocate all the resources needed for
this test.
2100
ABORT
System resources required for this test are not available.
1
FAIL
The system requires a TN780, TN2182, or TN2312 Tone-Clock
circuit to support the administered country-options tone-generation
parameters.
1. Check the administration on the system-parameters
country-option form. Specifically, the Base Tone Generation
Set on page 1 and any custom tone administration beginning
on page 2.
2. Replace any existing IPSI with a TN2312, or an existing
Tone-Clock circuits packs with a TN780 or TN2182.
PASS
The tone generation facility has been successfully refreshed with
its time-slot translation and system administration is consistent with
this type of Tone-Clock.
1. Display the Hardware Error Log via the display errors
command to make sure this circuit pack did not generate new
errors.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...