UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 May 2002
8-1711
555-233-143
H600-513 Cable Pinout
shows the pinout for the H600-513 cable assembly:
Administration
The TN2242 circuit pack requires board-level translation data. Before
administering any ports on the circuit pack, administer the following forms:
■
Circuit pack (change circuit-pack)
■
DS1 (add ds1)
■
Trunk group (add trunk-group n)
outlines the trunk group administration parameters that are
required for this interface to operate successfully in Japan.
Table 8-664.
H600-513 cable assembly pinout
TN2242
TDM
50-pin connection
pin number
Color
Lead Designation
Color
15-pin connection
pin number
22
W-BL
Line in +
W-BL
4
23
W-O
Line out -
W-O
9
47
Bl-W
Line in -
Bl-W
11
48
O-W
Line out +
O-W
2
Table 8-665.
TN2242 administration
Field
Value
Trunk Group form, Page 1
Trunk Type (in/out)
wink, delay, immed
(every permutation)
Trunk Signaling Type
blank
Answer Supervision Timeout
0
Receive Answer Supervision
y
Disconnect Supervision - In?
y
Disconnect Supervision - Out?
y
Incoming Dial Type
tone,
rotary,
mf (to other Avaya systems only)
Wink Timer for wink type
300
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...