Maintenance-Object Repair Procedures
555-233-143
8-1738
Issue 1 May 2002
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put every trunk or port of
the UDS1 Interface circuit pack into the out-of-service state.
2. Retry the reset board command.
1039
ABORT
The UDS1 Interface circuit pack is providing timing for the system. Therefore, it
cannot be reset without major system disruption.
If the UDS1 Interface circuit pack needs to be tested, set the synchronization
reference to another UDS1 Interface circuit pack or to the IPSI or Tone-Clock
circuit pack via the following command sequence:
1. Issue the disable synchronization-switch command.
2. Next, issue the set synchronization UUCSS command.
3. Lastly, issue the enable synchronization-switch command.
2000
ABORT
Response to the test request was not received within the allowable time period.
If Error Type 1538 is present in the Error Log, follow the maintenance strategy
recommended for this error type.
2012
ABORT
Internal system error
1. Retry the reset board command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the reset board command at 1-minute intervals up to 5 times.
FAIL
The UDS1 Interface circuit pack failed in the Internal Loop-Around test.
If the UDS1 connects to a T1 network facility or another switch:
1. Retry the reset board command at 1-minute intervals up to 5 times.
2. Enter the list measurement ds1-log UUCSS command to read the error
seconds measurement.
3. Verify that both endpoints of the DS1 link are administered using the same
signaling mode, framing mode, and line coding.
4. Check the physical connectivity of DS1 Interface circuit packs and cable.
5. Replace the local UDS1 Interface circuit pack and repeat the test.
6. Contact T1 Network Service to diagnose the remote DS1 endpoint.
Table 8-672.
Test #135 Internal Loop-Around Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...