UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 May 2002
8-1775
555-233-143
Translation Update Test (#146)
The Translation Update test sends the circuit-pack-level information specified by
System Administration to the UDS1 Interface circuit pack. Translation includes
the following data administered for a UDS1 Interface circuit pack (see output of
display ds1 UUCSS command): DS1 Link Length between two DS1 endpoints,
Synchronization Source Control, All Zero Suppression, Framing Mode, Signaling
Mode, Time Slot Number of 697-Hz Tone, Time Slot Number of 700-Hz Tone, etc.
If a TN464F or later UDS1 circuit pack is combined with a 120A1 CSU module or
the 401A T1 sync splitter to form an Integrated CSU module/T1 sync splitter, this
test will also send the administration for this Integrated CSU to the circuit pack to
assure the board’s translations are correct. The administration of the CSU
module/T1 sync splitter is done using the DS1 Circuit Pack administration form.
Translation for the CSU module/T1 sync splitter includes the following data:
Transmit LBO, Receive ALBO, Supply CPE Loop-Back Jack Power?, etc.
Table 8-681.
Test #146 Translation Update Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute interval s up to 5 times.
FAIL
Internal system software error.
1. Enter the display ds1 UUCSS command to verify the UDS1 Interface
circuit pack translation.
PASS
Translation data has been downloaded to the UDS1 Interface circuit pack
successfully.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...