UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 May 2002
8-1793
555-233-143
Table 8-686.
Test #1213 Far CSU Loop-Back Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the test ds1-loop UUCSS far-csu-loopback-test-begin command
at 1-minute intervals up to 5 times.
1005
ABORT
Far CSU Loopback test cannot be executed in the current configuration. To
run this, the TN464F or later suffix UDS1 must be administered for 24-channel
operation. The “Bit Rate” field on the DS1 circuit pack administration form must
be set to “1.544” for 24-channel operation.
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put every trunk or port of
the UDS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
1039
ABORT
The UDS1 Interface circuit pack is providing timing for the system. Executing
this test could cause major system disruption.
If the UDS1 Interface circuit pack needs to be tested, set the synchronization
reference to another DS1 Interface circuit pack or to the IPSI or Tone-Clock
circuit pack via the following command sequence:
1. Issue the disable synchronization-switch command.
2. Next, issue the set synchronization UUCSS command.
3. Lastly, issue the enable synchronization-switch command.
1950
ABORT
Another loopback/span test is already executing on the DS1 board or the board
is in a network requested loop-back mode (line loopback or payload loopback).
The hardware error log will indicate whether a Customer Loop-Back Jack test,
Far CSU Loopback test, or the One-Way Span test is executing or if the board
is in line-loopback or payload-loop-back mode. Only one long-duration
loopback/span test can be active at a given time. Thus, if a loopback/span test
is already active, that test must be terminated using the test ds1-loop UUCSS
end-loopback/span-test command in order to execute this test.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...