Maintenance-Object Repair Procedures
555-233-143
8-1806
Issue 1 May 2002
ICSU Status LEDs Test (#1227)
The UDS1 circuit pack has four status LEDs on the faceplate in addition to the
three standard faceplate LEDs. These four status LEDs are associated with the
120A1 Channel Service Unit (CSU) Module that can be connected to the
UDS1-BD board through the I/O connector panel behind the port carrier. The
UDS1-BD circuit pack, combined with the 120A1 CSU module or the 401A T1
sync splitter, forms an Integrated CSU (I-CSU).
This test is a visual test. It lights the four status LEDs red for 5 seconds, then
lights them green for 5 seconds, then lights them yellow for 5 seconds, then turns
the LEDs off and returns control of the status LEDs to the circuit pack.
This test is only be executed on TN464F or later suffix UDS1 circuit packs
administered for 24-channel operation (1.544 bit rate).
If the 120A1 CSU module or the 401A T1 sync splitter is not physically installed,
the status LEDs are always off and this test aborts.
Table 8-690.
Test #1227 ICSU Status LEDs Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
The ICSU Status LEDs test cannot be executed for the current configuration.
The test applies only to TN464F or later UDS1 circuit packs administered for
24-channel (1.544-Mbps) operation.
1. If the circuit pack is a TN464F or later suffix UDS1 circuit pack, then retry
the command.
1951
ABORT
The ICSU Status LEDs test cannot be executed because a 120A1 or later suffix
CSU module or a 401A or later suffix T1 sync splitter is not physically installed.
If using a 120A1 CSU module or the 401A T1 sync splitter, physically connect it
to the UDS1-BD board behind the port carrier. Otherwise, ignore this abort.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABORT
Internal system error.
1. Retry the command.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...