Test #1104 VC DSPPT Local TDM Loop-Back Test
Error
Code
Test
Result
Description / Recommendation
1000
1001
ABORT
System resources required to run this test are not available, or the port is busy
with a valid call.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The traffic load on the
system is very high, or time slots may be out-of-service due to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a Tone Detector for the test. The system is
oversized for the number of Tone Detectors present, or some Tone Detectors
are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
1004
ABORT
The port is seized by a user for a valid call. Use the status station command
for the station associated with this port and determine whether the port is
available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test was not received from the VC-BD circuit pack within the
allowable time period.
1. If this result occurs repeatedly, attempt to reset the port by using the
busyout port UUCSSpp and reset port UUCSSpp commands.
2. If this result occurs again, replace the circuit pack.
2012
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2103
ABORT
The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals up to 5 times.
0–3
FAIL
The TDM Loop-Around test failed.
1. Replace circuit pack.
4–7
FAIL
The Conference Circuit test failed.
1. Replace circuit pack.
PASS
The VC DSP Port Local TDM Loop-Around test passed.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...