XXX-BD (Common Port Circuit Pack)
Issue 1 May 2002
8-1885
555-233-143
Neon Test (#220)
This test checks the voltage required to light the neon lamp on an analog terminal.
A relay connects a 150V DC source from the backplane of the circuit pack onto
the voltage bus, and another relay connects a 2K shunt from the bus to ground.
Current in the line is then monitored to determine if the voltage is present. The
neon test runs only for TN746 and TN769 Analog circuit packs. If the circuit pack
is not a TN746 or TN769, the test will return PASS, but the test is not actually run.
Table 8-726.
Test #220 Neon Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Cannot get the list of translated ports on the circuit pack.
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the service state indicates that the port is in use, then
the port is unavailable for certain tests. Refer to the status commands
described in Chapter 8 for a full description of all possible states.) You
must wait until the port is idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
1008
ABORT
Could not allocate a ringing circuit. Either all the ringing circuits are in use, or
the ringing generator is defective or is not wired correctly.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error Log. If
an ABORT 1008 occurs for this test on other circuit packs as well, then the
ringing generator may be defective or is not wired correctly (see errors for
RING-GEN). If it does not occur on port test 48 for ANL-16-L, then all four
ring phases are in use.
2000
ABORT
Response to the request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
ABORT
Could not allocate the necessary system resources to run this test. Internal
system error.
1. If Error Type 1538 is present in the Error Log, follow the recommended
maintenance strategy.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...