EXTRA BD
This result can appear for Maintenance/Test, Call Classifier, Tone
Detector, Announcement, and Speech Synthesis circuit packs. Each of
these circuit packs has restrictions on how many can be installed in the
system or in a port network. The restrictions are as follows:
TN771D Maintenance/Test: 1 / port network
TN748 Tone Detector: 50 / system
TN744 Call Classifier: 25 / system
Speech Synthesizer: 40 / system
TN750 Announcement: 1 / system
Remove any extra circuit packs.
1
FAIL
For reset commands, the circuit pack was not successfully halted.
2
FAIL
For reset commands, the circuit pack was not successfully restarted after
being halted. For both results, replace the circuit pack.
FAIL
See the applicable maintenance object in
‘‘Maintenance-Object Repair Procedures’’
PASS
The requested action successfully completed. If the command was a
reset, the circuit pack is now running and should be tested.
Table 7-3.
Common Error Codes for Busyout, Release, Test, and
Reset Commands —
Continued
Error
Code
Command
Result
Description/Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...