Maintenance Commands
555-233-143
7-46
Issue 1 May 2002
busyout ipserver-interface
busyout ipserver-interface
Uc
The busyout command forces an IPSI to be out of service.
If the IPSI is not duplicated, this will cause a fallback to traditional control where
the EI is the AA, and the PKTINT functionality is moved to an IPSI in another port
network. If the IPSIs are duplicated in the port network, then the active IPSI
cannot be busied out IPSI also busies out the standby Tone-Clock. The required
argument is a cabinet/carrier.
Parameters
Examples
busyout ipserver-interface 6b
U
cabinet (1-64)
Specify the cabinet number you want to test.
c
carrier
Supply the carrier you want to test.