Maintenance Commands
555-233-143
7-48
Issue 1 May 2002
busyout journal-printer
busyout journal-printer pms-log | wakeup-log
The busyout journal-printer command puts the link to the Property Management
System log or wakeup log printers in a maintenance busy state. (See Busyout
and Release Commands at the beginning of this chapter). When busied out, the
link is dropped and no data transfer can take place over it.
This command can be used to prevent unwanted interference between different
maintenance processes. Maintenance software may put a component that is part
of a link in a busy state, causing link set-up to fail, and resulting in attempts by the
system to reestablish the link. If a maintenance test requires that the component
be idle, frequent attempts at re-setup may delay the recovery of a faulty
component. Busying out the link will prevent re-setup attempts.
Parameters
Examples
busyout journal-printer pms-log
busyout journal-printer wakeup-log
For more information, see the following sections:
,
‘‘Common Output Fields’’ on page 7-9
, and
pms-log
Busies out the link to the Property Management System printer
wakeup-log
Busies out the link to the Wakeup Log printer
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...