Maintenance Commands
555-233-143
7-72
Issue 1 May 2002
change synchronization
This command is destructive.
This command changes the synchronization source to the system.
Cabinet number only applies to S8700 IP Connect configurations
Output
The following example shows the output for the
change synchronization
command for an S8700 IP Connect configuration.
Table 7-10.
change synchronization command parameters
Action/ Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
change
synchronization
cabinet*
number
1-64
init
inads
craft
none
none
change synchronization 1 Page 1 of 2
SYNCHRONIZATION PLAN
CABINET 1
SYNCHRONIZATION SOURCE (circuit pack location)
Stratum: 4
Primary: 01B02 Secondary: 01A08
CIRCUIT PACKS AVAILABLE FOR SYNCHRONIZATION
Location Type Name Slip Location Type Name Slip
01B05 DS1 GERT<>Lulu n
01A08 DS1 Gertrude <> 5E y
01A09 DS1 GERT Loop 414 y
01B02 DS1 gertrude <> st1 y
NOTE: DS1 and BRI TRUNK sources result in stratum 4, type II synchronization