Maintenance Commands
555-233-143
7-150
Issue 1 May 2002
Interval
The length of this schedule in weeks. If this field is 0 (default), the schedule
runs on the specified days only once.
OTL Throttle
The number of trunk members (1 – 4) tested concurrently during a
schedule. If this field is set to 1, the OTL (originating test line) tests each
trunk sequentially. If set from 2 to 4, the specified number of trunks are
tested in parallel.
Test Type
One of the following types of test to be performed on the trunk
group/members in this schedule:
■
full (default) runs the most comprehensive test and collects every
associated measurement for each TTL type.
■
supv performs a supervision test and only confirms the presence of
the test set at the far end. No measurements are taken for this test.
■
no-st runs the "full" test, but skips any self-test sequences. This saves
about 20 seconds on the type 105 test and does not have any effect on
type 100 or 102 tests.
■
no-rl runs the "full" test, but skips any return-loss sequences. This
saves about 20 seconds on the type 105 test and does not have any
effect on type 100 or 102 tests.
■
no-st/rl runs the "full" test, but skips every self-test and return-loss
sequence. This saves about 40 seconds on the type 105 test and does
not have any effect on type 100 or 102 tests.
Duration
The maximum number of hours (1 to 24) a schedule can remain active.
Schedules continue to run until every trunk group/member for that
particular schedule is tested or until the scheduled duration elapses. If the
duration elapses before every trunk group/member can be tested, the
schedule stops.
Trk Trp
The trunk-group numbers to be tested when this schedule runs. There is
no limit to the number of times that a trunk group can appear on any
particular schedule, or to the number of different schedules in which a trunk
group can appear. Default is blank.
Bgn Mbr
The beginning member number of the trunk group to be tested; default is 1.
End Mbr
The ending member number of the trunk group to be tested. This value
must be greater than or equal to the value of the beginning member field.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...