get boot-image
Use this command to view the two firmware image parameters on the TN2501AP
circuit pack.
Output
Screen 7-11.
Display Firmware Image(s) screen
Field Descriptions
Table 7-19.
display firmware-image command parameters
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
get boot-
image
location
The physical location of the
circuit pack (UUCSS).
Example:
get boot-image 1C07
init
inads
craft
customer
Board Type
For VAL, this field is TN2501.
FW Vintage
The firmware vintage number
HW Signature
The hardware signature number
Suffix
The circuit pack suffix code letter
Date
The date the firmware file was created or transferred to the circuit pack
Timestamp
The time that the firmware file was created or transferred to the circuit pack
get boot-image 1C07
DISPLAY FIRMWARE IMAGE(S)
Image 1 Image 2
Board Type: TN2501 TN2501
FW Vintage: 02 02
HW Signature: 02 02
Suffix: A A
Date: 03/02/02 03/02/01
Timestamp: 10:30:50 12:42:18
CRC Checksum: Good Good
Active Image: Yes No
Reboot Image: Yes No
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...